Commit Graph

6 Commits

Author SHA1 Message Date
Brummel bc88e18247 feat(engine,cli): GraphBuilder gang cadence + render carrier (#61 tasks 5-6)
Builder: NodeHandle::param -> ParamRef, GraphBuilder::gang, build() resolves
the gang table (collect-then-reject, BuildError::{UnknownParam,AmbiguousParam,
BadGang}) and terminates in Composite::with_gangs — the same predicate the
op-script and serde boundaries use. C24 lockstep extended: an op-script gang
replay serializes byte-identically to the GraphBuilder twin (FlatGraph edges +
sources + canonical JSON).

Render: model_to_json emits a per-scope gangs fragment (name, kind, [node,pos,
"param"] members) for ganged scopes only — the gang-free model stays
byte-identical (model_golden untouched). graph-viewer.js annotates a ganged
open param with its public knob name; guarded by a viewer_gang_param.{mjs,rs}
pair RED-first per the established viewer_bound_param convention (a welcome
extra beyond the plan's file list).

Ratified deviation: the model's kind string uses the serde form ("I64") — the
plan's implementation snippet (kind_str -> "i64") contradicted its own test;
resolved toward the test + the blueprint_serde form. Two quality nits held as
principled plan-holds (inline resolution block; the unreachable unwrap_or
placeholder check_gangs refuses first).

Verified: aura-engine lib 264/0 (model_golden, lockstep, builder, carrier all
green), viewer_gang_param 1/0, workspace clippy -D warnings clean. Slice
resumed across a transient API failure via workflow resume (cached prefix).

refs #61
2026-07-10 13:03:10 +02:00
Brummel 521cfc8b5b feat(engine,cli): gang serde + identity + the gang construction op (#61 tasks 3-4)
Serde: CompositeData carries an additive-optional gangs section (omitted when
empty — every existing v1 document round-trips byte-identically, NO
format-version bump per the #61 decision; BLUEPRINT_FORMAT_VERSION doc now
records the pre-ship Tier-2 dormancy). project() emits gangs canonically
(members by (node,pos), gangs by first member) so declaration order never
reaches the content id; reconstruct() re-mints through Composite::with_gangs
and a corrupted section refuses as the new typed LoadError::Gang.
strip_debug_symbols blanks gang + member names, keeps (node,pos,kind) — the
identity id stays gang-name-blind and gang-structure-sensitive.

Construction: Op::Gang { as_name, into } with the feed-style two-phase eager
arm (member resolution against the post-bind schemas, kind uniformity,
single-gang membership; OpError::{GangKindMismatch,AlreadyGanged,GangArity});
finish() routes the assembled composite through with_gangs, and gang-name
collisions surface via the existing injectivity gate on the projected space.
CLI: OpDoc::Gang ({"op":"gang","as":…,"into":[…]}), kind_label/From/
format_op_error arms, and format_load_error phrases gang faults as prose
(gang_fault_prose) instead of leaking Debug — a ratified improvement over the
plan bytes.

Held quality nit (principled plan-hold): gang()'s inline collect-then-reject
param resolution is the module's established convention (bind/try_bind); a
shared cross-crate helper is out of this task's scope.

Verified: workspace build clean, aura-engine lib 258/0, aura-cli
graph_construct 48/0 (incl. the new gang-op e2e), clippy -D warnings clean.

refs #61
2026-07-10 11:57:16 +02:00
Brummel f1ab81d1b8 feat(0089): construction diagnostics read by-identifier (closes #162)
The cycle-0088 fieldtest found three presentation defects on the construction
op-script surface, all where the surface dropped out of its by-identifier register.
Presentation only — every fault still fires identically (same exit code, same
op/finalize attribution); only the rendered cause changes.

- Item 1 (finalize by-identifier). The holistic finalize fault leaked the raw
  index Debug form (`UnconnectedPort { node: 2, slot: 1 }`). `GraphSession::finish()`
  now translates the three reachable index-carrying CompileErrors into new
  by-identifier OpError variants (UnconnectedPort{node,slot} / RoleKindMismatch{role}
  / UnboundRootRole{role}) using the session's `ids`/`schemas` and the composite's
  `input_roles()` — the holistic gate calls (validate_wiring,
  check_param_namespace_injective, check_root_roles_bound) stay byte-for-byte
  unchanged (C24: no second validator; only the `.map_err` closures changed).
  `aura graph build` now prints `finalize: slot sub.rhs is unconnected`.
- Item 2 (bind mismatch prose). `format_op_error`'s BadParam arm matches the
  BindOpError variants instead of `{:?}`: `op 1 (add): param fast.length expects I64
  but got F64`, matching the connect mismatch register.
- Item 3 (discoverable bind form). `introspect --node` shows the typed-Scalar bind
  form: `param length:I64  (bind {"I64": <v>})`.

Item 1 spans both crates atomically (adding OpError variants forces the exhaustive
format_op_error match; the finish() translation flips behavioural test pins in both
crates). Five test touches: the two in-file unit tests, the two E2E twins plan-recon
found that the spec's testing strategy under-enumerated
(construction_e2e.rs, tests/graph_construct.rs), and a new unbound-root-role test;
the implementer added RoleKindMismatch / Ambiguous/UnknownParam coverage too. The
CLI finalize test was tightened (orchestrator) to pin `sub.rhs` and the absence of a
raw `node:` index.

Spec boss-signed on a grounding-check PASS (docs/specs+plans/0089). Verified: full
workspace suite + clippy green; the three messages reproduce exactly against the
built binary on the fieldtest fixtures.
2026-06-30 11:49:03 +02:00
Brummel 16520429be fix(0088): reject dataflow cycles in construction build (closes #161)
The construction op-script service accepted a dataflow cycle and exited 0,
emitting a non-DAG blueprint — violating domain invariant 5 / C9 (the graph is a
DAG; the only feedback path is an explicit delay/state node). The cycle-0088
fieldtest surfaced it (fieldtests/cycle-0088-construction-op-script/FINDINGS.md).

The construction gate set had no acyclicity check: a cyclic interior-edge set
passed both the eager per-op gates and the holistic finish, so replay() returned
Ok. Fix: an eager reachability check at the connect op that closes the cycle —
GraphSession::closes_cycle(from, to) asks "does the `to` node already reach the
`from` node through the edges added so far?" and rejects with a new by-identifier
OpError::WouldCycle { from, to } ("connecting from -> to would close a cycle"),
threaded through the CLI's exhaustive format_op_error. The fault is attributed to
the offending connect op, consistent with the surface's eager per-op diagnostics.

Eager rather than a holistic topological check at finish: a cycle is closed by
one specific connect, and naming that connect is the sharpest by-identifier error.

RED-first: two tests pin the symptom (a 2-cycle a<->b and a self-loop), both red
before the fix and green after; the 19 existing construction tests, the full
workspace suite, and clippy stay green.

Scope is the cycle only. The validity-floor cases the fieldtest also noted (an
unfed declared source role, an output-less graph) are degenerate-but-well-formed,
not invariant violations, and are deferred (refs #161) pending the build->consume
edge (#28) that defines what a valid emitted blueprint must guarantee.
2026-06-30 10:48:03 +02:00
Brummel 86841b0740 audit(0088): cycle close — drift fixes + C24 ledger refresh; close construction service
Architect drift review of cycle 0088 (#157, the introspectable fail-fast
construction service: §A shared gate predicates, §B the GraphSession/Op/replay
per-op surface + introspection, §C the aura graph build/introspect CLI).

What holds (confirmed against the diff): no-second-validator (C24) — edge_kind_check
is the single kind-check site called by both validate_wiring and
GraphSession::connect, and validate_wiring / check_param_namespace_injective are
reused verbatim in finish(); engine domain-free (invariant 9) — construction takes an
injected Fn(&str)->Option<PrimitiveBuilder>, no registry, the closed match +
std_vocabulary_types live in aura-std; topology-as-data / no DSL (C24/C17/inv 10) —
the engine Op is serde-free, the OpDoc wire DTO is CLI-side, ops are static and
non-Turing-complete; replay-equals-builder byte-identity (construction_e2e.rs) protects
C9/C19/C23.

Resolution:
- fix (drift-med): the root-role-boundness gate was the one holistic check finish()
  re-implemented instead of sharing — extracted check_root_roles_bound (blueprint.rs)
  and called from BOTH compile_with_cells and finish(), so finish() now reuses ALL the
  holistic gates and the no-second-validator claim is literally true. Behaviour-
  preserving (same UnboundRootRole variant; unbound_root_role_is_rejected stays green).
- fix (drift-med): removed the #![allow(dead_code)] on construction.rs — empirically
  unnecessary (the pub re-exported surface is reachable; clippy -D warnings green
  without it) — and its now-inaccurate comment (it claimed removal "when the consumer
  lands", but the consumer is a separate crate). Also tidied a stale graph_construct.rs
  module-doc line.
- fix (ledger): C24 Status refreshed — #157 moved out of "Remaining" with a cycle-0088
  realization note (the construction service: eager/holistic gate split, build-free
  introspection, emits the #155 blueprint); #159 reframed as paired with #157.
- carry-on (debt-med, forward-noted): the std_vocabulary roster is now a third hand-kept
  copy (match + test list + std_vocabulary_types) and introspect --vocabulary escalates
  #160's gap to user-facing — noted on #160; still fails safe.
- carry-on (scaling-low, forward-noted): the engine Op -> wire OpDoc direction is
  unguarded for future Op variants — noted on #156 (the format-extension track).

No architect-sweep / regression script is declared in the project facts, so the suite
is the gate: cargo test --workspace 51 suites green; clippy --all-targets -D warnings
clean. Cycle drift-clean.

Ephemeral cycle artifacts removed (lifecycle convention): docs/specs/0088-*,
docs/plans/0088-*.

closes #157
2026-06-29 21:48:40 +02:00
Brummel 27ac4dc537 feat(0088): §B construction op-script surface — GraphSession/Op/replay + introspection
Iteration-1 §B of the construction service (#157), on the §A shared predicates
(ea1ca32): a declarative, replayable by-identifier op-script that builds a
runnable blueprint through validated ops, reusing the engine's existing gates at
two cadences — no second validator (C24).

- construction.rs: `Op` (Source/Input/Add/Feed/Connect/Expose, 1:1 with the
  document, dotted by-identifier ports), `OpError` (by-identifier causes),
  `GraphSession` (per-op-fallible accumulator) and the free `replay` driver
  (stop-at-first-failing-op, naming it by `(op_index, OpError)`).
  - Eager (per-op): name resolution + edge_kind_check + the >1-cover
    DoubleWiredPort arm + try_bind — all calling the §A shared predicates.
  - Holistic (finish): the 0-cover totality arm, param-namespace injectivity, and
    root-role boundness — the SAME unchanged engine gates
    (check_param_namespace_injective / validate_wiring), now at end-of-document.
  - Build-free introspection: `unwired()` (a partial document's still-open slots).
- aura-std std_vocabulary_types(): the enumerable companion to the closed
  std_vocabulary match (a `fn(&str)->Option<…>` resolver cannot be listed),
  lockstep-tested in the list->resolver direction; the reverse fails safe (#160).
- aura-engine exports replay/GraphSession/Op/OpError + re-exports BindOpError.

Acceptance (engine level): a sink-free price->fast/slow SMA->Sub->Bias signal
root built through the ops compiles to a FlatGraph byte-identical (edges +
sources) to its GraphBuilder twin (C1); an invalid op is rejected at the op,
named; vocabulary + unwired slots answer without a build. Pinned by
construction.rs unit tests + a construction_e2e.rs integration test over the
public seam the iteration-2 CLI will consume.

Notable judgement calls folded in from the implement loop: feed is all-or-nothing
(two-phase resolve-then-commit, no partial wiring on a mid-fan-out fault); the
node identifier is stamped onto the builder (`named(&id)`) so two same-type nodes
get distinct param paths and do not trip the injectivity gate prematurely; a
module-level `#![allow(dead_code)]` covers the public surface until the
iteration-2 CLI consumes it. Full suite green; clippy --all-targets -D warnings
clean.

Iteration 2 (the JSON op-list encoding + `aura graph build`/`introspect` CLI)
remains; #157 stays open. refs #157
2026-06-29 20:28:41 +02:00